A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HSiemens Scalance X200 4pirt
HWSiemenswszystkie wersjeSiemens Scalance X200 4pirt Firmware
OSSiemens< 5.5.0Siemens Scalance X201 3pirt
HWSiemenswszystkie wersjeSiemens Scalance X201 3pirt Firmware
OSSiemens< 5.5.0Siemens Scalance X202 2irt
HWSiemenswszystkie wersjeSiemens Scalance X202 2irt Firmware
OSSiemens< 5.5.0Siemens Scalance X202 2pirt
HWSiemenswszystkie wersjeSiemens Scalance X202 2pirt Firmware
OSSiemens< 5.5.0Siemens Scalance X202 2pirt Siplus Net
HWSiemenswszystkie wersjeSiemens Scalance X202 2pirt Siplus Net Firmware
OSSiemens< 5.5.0Siemens Scalance X204irt
HWSiemenswszystkie wersjeSiemens Scalance X204irt Firmware
OSSiemens< 5.5.0Siemens Scalance X307 3
HWSiemenswszystkie wersjeSiemens Scalance X307 3 Firmware
OSSiemenswszystkie wersjeSiemens Scalance X307 3ld
HWSiemenswszystkie wersjeSiemens Scalance X307 3ld Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2
HWSiemenswszystkie wersjeSiemens Scalance X308 2 Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2ld
HWSiemenswszystkie wersjeSiemens Scalance X308 2ld Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2lh
HWSiemenswszystkie wersjeSiemens Scalance X308 2lh\+
HWSiemenswszystkie wersjeSiemens Scalance X308 2lh Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2lh\+ Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2m
HWSiemenswszystkie wersjeSiemens Scalance X308 2m Firmware
OSSiemenswszystkie wersjeSiemens Scalance X308 2m Ts
HWSiemenswszystkie wersjeSiemens Scalance X308 2m Ts Firmware
OSSiemenswszystkie wersjeSiemens Scalance X310
HWSiemenswszystkie wersjeSiemens Scalance X310fe
HWSiemenswszystkie wersje
Related vulnerabilities
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker w...
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All...
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANC...
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All ...
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All ...