CRITICAL🇵🇱 Wersja polska

CVE-2024-41792

CVSS 9.2v4.0pub. 2025-04-08upd. 2025-09-23

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.

CVSS Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
  • Siemens 7kt Pac1260 Data Manager

    HW
    Siemens
    wszystkie wersje
  • Siemens 7kt Pac1260 Data Manager Firmware

    OS
    Siemens
    wszystkie wersje
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
Tags
Path TraversalAuth Bypass
CWE
References

Related vulnerabilities

CVE-2024-41788CRITICAL9.4PL ✓ten sam produkt

Command Injection w Siemens SENTRON 7KT PAC1260 Data Manager – RCE jako root

CVE-2024-41789CRITICAL9.4PL ✓ten sam produkt

Command Injection w Siemens SENTRON 7KT PAC1260 Data Manager

CVE-2024-41790CRITICAL9.4PL ✓ten sam produkt

Command injection w Siemens SENTRON 7KT PAC1260 Data Manager — RCE jako root

CVE-2024-41794CRITICAL10.0PL ✓ten sam produkt

Hardcoded credentials z dostępem root w Siemens SENTRON 7KT PAC1260 Data Manager

CVE-2024-41793HIGH7.7ten sam produkt

A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of a...