CRITICAL🇵🇱 Wersja polska

CVE-2025-30042

CVSS 9.0v4.0pub. 2026-03-02upd. 2026-03-09

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.

CVSS Vector
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
  • Cgm Clininet

    APP
    Cgm
    < 2025.ms2
🔵
CHECK WITH VENDOR
No clear patch data available. Check vendor references.
CWE
References

Related vulnerabilities

CVE-2025-58402HIGH7.1ten sam produkt

The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorizati...

CVE-2025-58405MEDIUM5.3ten sam produkt

The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP...

CVE-2025-58406MEDIUM5.3ten sam produkt

The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side at...